- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Espinosa-Momox, Ana (1)
-
Norton, Brandon (1)
-
Porras-Aguilar, Rosario (1)
-
Serrano-García, David_I (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract There is a significant gap in cost-effective quantitative phase microscopy (QPM) systems for studying dynamic cellular processes while maintaining accuracy for long-term cellular monitoring. Current QPM systems often rely on complex and expensive voltage-controllable components like Spatial Light Modulators or two-beam interferometry. To address this, we introduce a QPM system optimized for time-varying phase samples using azobenzene liquid crystal as a Zernike filter with a polarization-sensing camera. This system operates without input voltage or moving components, reducing complexity and cost. Optimized for gentle illumination to minimize phototoxicity, it achieves a 1 Hz frame rate for prolonged monitoring. The system demonstrated accuracy with a maximum standard deviation of ±42 nm and low noise fluctuations of ±2.5 nm. Designed for simplicity and single-shot operations, our QPM system is efficient, robust, and precisely calibrated for reliable measurements. Using inexpensive optical components, it offers an economical solution for long-term, noninvasive biological monitoring and research applications.more » « less
An official website of the United States government
